Emberglow CSO24NG Guía de instalación Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
4
D. Prefabricated fireplace: Refer to the manufactures fireplace instruction manual for specific
information regarding the running of a gas line into that particular model. A typical installation
involves the insertion of a 1/2 inch gas pipe through the gas line tube provided by the man-
ufacturer from outside the fireplace.The Knockout on the inside of the fireplace is removed
as the gas pipe is punched through the fireplace. (See Figure 3).
E. Masonry fireplace: A 1/2 inch gas supply line must be provided to the firebox. Most install-
access hole through the masonry wall. The supply line should be
secured and sealed by mortar within the access hole. The supply line should also have a
hole.
shutoff valve either in the wall or inside the fireplace (see Figure 4).
GAS LOG INSTALLATION
(See Figure 1 Parts List as a guide to reference part numbers.)
BURNER PAN INSTALLATION
NOTE: Use pipe compound on all male threads to seal joints.
A.  


Brace panon workbench when removing burner
knock-out.
B.
Locate 3/8” locknut (Part #12) and washer (Part #21), and
attach them to the 3/8” brass ori
fice elbow (Part #11) Do
not fasten the locknut on the “ flared” end.
C.
Slide the 3/4” burner support spacer (Part # 10) over the
Dual Burner bar (Part #9) and move spacer to opposite
side of the gas inlet connection (See Figure 5).
D.
Secure the intake end of the Dual burner bar (Part # 9)
to the burner pan (Part # 8) through the knock-out hole
selected (right or left hand) with the 3/8” brass orifice
elbow (Part # 11),3/8” locknut (Part # 12), and washer
(Part #21) previously assembled in Step B (See Figure 6).
E. Tighten elbow until
firmly attached to the Dual burner bar.
Then, firmly tighten the attached lock-nut on the elbow to
seal the burner bar to the wall of the burner pan.
Figue3. Gas line installation - Prefabricated Fireplace
Figure 4. Gas line installation - Masonry Fireplace
Figure 5. Burner bar placement
Figure 6. Burner bar connection
ations require drilling an
NOTE:
Strike knock-out plug with a punch or drift.
Vista de pagina 3